Honeywell L4006E1067 - High Limit Aquastat, 130-270°F range, Manual Reset - The Honeywell L4006E1067 is temperature limiting aquastat controller that is manually reset. It is designed for high limit applications and has a temperature range of 130 to 270 degrees F. This dryer was manufactured with a manual reset burner hi-limit and basket (tumbler)/lint chamber hi-limit thermostat which is monitored by the Phase 7 computer. If the burner is open prior to start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 7 computer will display “BURNER HIGH LIMIT FAULT” with an.
![]()
Advertising
IMPORTANT
This dryer is equipped with a burner
Honeywell Manual Reset High Limit
Most similar email client to outlook for mac. hi-limit and tumbler/lint chamber hi-limit
Epson xp 410 software mac download. thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N:114093
SECTION X
BURNER AND BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
Wifilink 5100 agn driver. MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR PHASE 7 MODELS
Boiler Manual Reset High Limit![]()
This dryer was manufactured with a manual reset burner hi-limit and basket (tumbler)/lint chamber
hi-limit thermostat which is monitored by the Phase 7 computer. If the burner is open prior to start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 7 computer will display “BURNER HIGH LIMIT FAULT” with an audio indication. Harmless vst full download. If the basket (tumbler)/lint chamber hi-limit thermostat is open prior to start, the display will read “EXHAUST HIGH LIMIT FAULT” with an audio indication as well.
If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable error
code described above, along with an audio indication. If the drum temperature is above 100° F (38° C), the dryer will continue to run with no heat for 3 minutes or until the drum temperature has dropped below 100° F (38° C). The clear/stop button on the Phase 7 keyboard (touch pad) must be pressed to clear the error Ati radeon 9200se 128mb driver windows 7. condition. The open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
operation.
The location of the burner hi-limit is on the right side of the burner box and the basket (tumbler) hi-limit is located
in the lint chamber area.
WARNING https://ygctjl.weebly.com/singer-sewing-machine-g-series-user-manual.html. : Discontinue power to dryer before attempting to reset hi-limit.
Manual Reset High Limit Switch
Advertising
Reset High Limit Switch
Popular Brands
Honeywell Manual Reset High Limit Aquastat
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |